






LFT-2CH Pro 2-Channel Flicker Tester
型号: LFT-2CH Pro
Compliance with ISO16505/GB15084 standards?2-Channel model?2.5MHz sample rate on 2 channels
产品详情
LFT-2CH PRO 2-Channel Flicker Tester,a state-of-the-art device specifically designed for measuring and analyzing the flickering characteristics of displays. With its advanced features including a high-speed light probe and cutting-edge software, it is well-equipped to meet the diverse testing needs of research and production applications.
The system is equipped with a highly responsive photodetector that works seamlessly with the high-speed data acquisition system, enabling rapid and accurate measurement of the photometric quantity. Its unique signal processing algorithm provides exceptional anti-interference capabilities, allowing for quick and precise identification of various indicators such as the stroboscopic frequency of the tested light source.
With the LFT-2CH PRO 2-Channel Flicker Tester, you can confidently meet the flicker testing requirements of various standards, especially in the automotive industry. Its exceptional performance, reliable data analysis, and user-friendly interface make it an indispensable tool for researchers and manufacturers.
▋ Key Features
High-Speed Light Probe: The system incorporates a light detector coupled with a high-speed data acquisition system, enabling rapid measurement of light intensity.
Robust Signal Processing Algorithm: The unique signal processing algorithm empowers the system with exceptional interference resistance. It can quickly and accurately identify the flicker frequency and other related indicators of the tested light source.
▋ Product Advantages
Compliance with CMS Automotive Electronic Rearview Mirror ISO16505/GB15084 Requirements for Monitor Flicker Testing.
High-Speed Signal Acquisition: The system achieves fast signal acquisition, with a maximum sampling frequency of 2.5MHz.
Calculation of E_pred and E_obs Values: Working in conjunction with the analysis software, the system provides the required E_pred and E_obs values for monitor evaluation.
User-Friendly Software: The software boasts a simple and stable interface, ensuring ease of use.
▋ Specification
Product Name | LFT-2CH Pro |
Dimension | 254(L)x166(W)x81(H)mm |
Number of probe channels | Support 2 channels input at the same time |
Sample frequency | Max 2.5MHz |
ADC resolution | 16 bit |
Interface | USB |
Power supply | 100-240V 50/60Hz 1.5A |
Data analysis | Collect data directly through the analysis software, and get the E_pred and E_obs data required by the monitor CMS test |
Spectral Response Range | 320-730nm |
Peak Sensitivity Wavelength | 560nm |
Rise Time | 2.5μs(tr VR=0V RL=1KΩ) |
▋ Product Display
CMS LAB Model ↓
——————————————————————————————————————————————————————————